人人射人人干-最新国产成人ab网站-啪啪免费网-极品国产91在线网站-我爱av好色-欧美丰满一区二区免费视频-国产精品高潮呻吟av久久-精品深夜av无码一区二区老年-av手机在线观看-成人a网站-欧美成人免费一级人片100-精品久久一区-成年人视频在线观看免费-永久免费看啪啪的网站-黄大色黄大片女爽一次-综合欧美日韩-香港午夜三级a三级三点在线观看

High precision weighing and force measuring sensors
Tel:

156-2185-0939

Loaction :HOME>> NEWS>>Industry news

Tel:

156-2185-0939

Method for proper installation of pressure sensors

Author:Browse:2066文章來源:m.3060078.cnTime:2020-07-22

Intro:

Proper installation method of pressure sensor: (1) Verify the frequency response value of the pressure sensor under normal atmospheric pressure and standard temperature conditions with an appropriate instrument.

Proper installation method of pressure sensor:

(1) Verify the frequency response value of the pressure sensor under normal atmospheric pressure and standard temperature conditions with an appropriate instrument.

(2) Verify the correctness of the coding of the pressure sensor and the corresponding frequency response signal.

Determine the specific installation location


In order to determine the number and specific installation location of the pressure sensor, it is necessary to consider each inflating section of the inflating net.

(3) One cable shall be installed at the beginning and end of each cable respectively.

(4) The pressure sensor is installed along the cable, which is better installed at the cable connection.

Pressure sensor

(5) One cable should be installed at the change of cable laying mode (overhead, underground)

(6) For the non-branched cable, the installation interval of the pressure sensor is less than 500m due to the same cable program of the barrier line, and the total number is no less than 4.

(7) In order to determine the fault point of the pressure sensor, in addition to installing the pressure sensor at the starting point, 150~200m away from the starting point, there is another installation. Of course, in the design, economic and technical factors must be considered. In the place where the pressure sensor is not needed, it should not be installed.

(8) Each cable shall be equipped with no less than 4 pressure sensors. The distance between the two pressure sensors near the telephone station shall not be too wide

(9) One branch point of each cable should be installed. If the two branch points are close to each other (less than 100 m), only one branch point can be installed.

友情鏈接/LINKS
中  文English
高要市| 闽清县| 彭山县| 林口县| 大连市| 湟中县| 高台县| 遂川县| 班玛县| 乐山市| 彰武县| 黄浦区| 钦州市| 聂荣县| 常州市| 高唐县| 南郑县| 宜兴市| 嵊州市| 平阴县| 梁平县| 广西| 阿瓦提县| 永清县| 宁化县| 上林县| 田东县| 古浪县| 连山| 甘谷县| 府谷县| 新平| 腾冲县| 平安县| 大化| 通海县| 伊宁市| 天水市| 大名县| 无极县| 徐水县|